      www.su-jiao.com/ul/
         | 
      E67171  |  | 
      LG CHEMICAL LTD |  | 
      20 YOIDO-DONG, YONGDUNGPO-GU, SEOUL  150-721 KR |  | 
        LUPOY GP-1006F, LUPOY GP-1006F(m)(#) |  | 
        Polycarbonate (PC), modified, furnished as pellets |   
    |   | Min Thk | Flame |   |   | RTI | RTI | RTI |  | Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |  | ALL | 1.0 | V-0 | - | - | 80 | 80 | 80 |   | 1.5 | V-0 | 3 | 0 | 120 | 110 | 120 |   | 2.5 | V-0,5VA | - | - | 120 | 110 | 120 |   | 3.0 | V-0,5VA | 2 | 0 | 120 | 110 | 120 |   
    | Comparative Tracking Index (CTI): | 2 | Inclined Plane Tracking (IPT): | - |  | Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm) : | - |  | High-Voltage Arc Tracking Rate (HVTR): | 3 | High Volt, Low Current Arc Resis (D495): | 7 |  | Dimensional Stability (%): | - |  |  |   
    | (#) -  | May be followed by optional suffix letter from A-Z incl., except F, and except Grades AF302G, HT700B, XR401B, LI912A, AF303G, AF303S, XR404T, XR407D, XR407E, HF380X. |  | (m) -  | May be followed by 1 or 2 suffix letters from A-Z incl., except F, FF, FH. |   
    | ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |   
    | 
        Report Date:
        1997-12-11
        Last Revised:
        2006-01-05 | 
        qq:27660005 | 
         |   
    
    
      
      
      
      
       |  |  | Thickness |  |  | Test Name | Test Method | Units | Tested (mm) | Value |  | Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 1.0 | V-0 (ALL) |   |  |  | 1.5 | V-0 (ALL) |   |  |  | 2.5 | V-0,5VA (ALL) |   |  |  | 3.0 | V-0,5VA (ALL) |  | Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |  | Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |  | IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |  | IEC Ball Pressure | IEC 60695-10-2 | C | - | - |  | ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |  | ISO Tensile Strength | ISO 527-2 | MPa | - | - |  | ISO Flexural Strength | ISO 178 | MPa | - | - |  | ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |  | ISO Izod Impact | ISO 180 | kJ/m2 | - | - |  | ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |   
      
    
    
   |