      UL黄卡su-jiao.com/ul/
         | 
      E41179  |  | 
      MITSUBISHI ENGINEERING-PLASTICS CORP |  | 
      ENVIRONMENT & QUALITY ASSURANCE DEPT, DIV 1, SHIODOME SUMITOMO-BLDG 25TH FL, 1-9-2 HIGASHI-SHINBASHI, MINATO-KUTOKYO105-0021 JP |  | 
        AN70(+)(f2) |  | 
        Polyphenylene Oxide (PPHOX), "Iupiace", furnished as pellets |   
    |   | Min Thk | Flame |   |   | RTI | RTI | RTI |  | Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |  | ALL | 0.75 | V-0 | 1 | 3 | 110 | 105 | 110 |   | 1.5 | V-0 | 1 | 3 | 110 | 105 | 110 |   | 2.0 | V-0, 5VB | 1 | 3 | 110 | 105 | 110 |   | 2.5 | V-0, 5VA | 1 | 3 | 110 | 105 | 110 |   | 3.0 | V-0, 5VA | 1 | 3 | 110 | 105 | 110 |   
    | Comparative Tracking Index (CTI): | 1 | Inclined Plane Tracking (IPT): | 120 min at 1.5kV |  | Dielectric Strength (kV/mm): | 32 | Volume Resistivity (10x ohm-cm) : | 16 |  | High-Voltage Arc Tracking Rate (HVTR): | 0 | High Volt, Low Current Arc Resis (D495): | 7 |  | Dimensional Stability (%): | 0 |  |  |   
    | (f2) -  | Subjected to one or more of the following tests: Ultraviolet Light, Water Exposure or Immersion in accordance with UL 746C, where the acceptability for outdoor use is to be determined by UL. |  | + -  | Suffix optional, exceptions: The following cannot be used as optional suffixes: "T" for grade 2030, "A" for 1501, 1502, 1511, 1521 & 2502, "N" for NXG5050, NXG5030, NXG5501, & CGF-(v)(u),"S1" for F20-54. |   
    | ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |   
    | 
        Report Date:
        1983-02-10
        Last Revised:
        2013-08-20 | 
        邮箱:admin@su-jiao.com | 
         |   
    
    
      
      
      
      
       |  |  | Thickness |  |  | Test Name | Test Method | Units | Tested (mm) | Value |  | Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 0.75 | V-0 (ALL) |   |  |  | 1.5 | V-0 (ALL) |   |  |  | 2.0 | V-0, 5VB (ALL) |   |  |  | 2.5 | V-0, 5VA (ALL) |   |  |  | 3.0 | V-0, 5VA (ALL) |  | Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |  | Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |  | IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |  | IEC Ball Pressure | IEC 60695-10-2 | C | - | - |  | ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |  | ISO Tensile Strength | ISO 527-2 | MPa | - | - |  | ISO Flexural Strength | ISO 178 | MPa | - | - |  | ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |  | ISO Izod Impact | ISO 180 | kJ/m2 | - | - |  | ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |   
      
    
    
   |