             vailability  
             | 
            
            
  | 
        |||
| 
             Features  
             | 
            
            
  | 
        |||
| 
             Forms  
             | 
            
            
  | 
        
| Physical | 
             Nominal Value 
             | 
            
             Unit 
             | 
            
             Test Method 
             | 
        
| 
             Specific Gravity 
             | 
            
             1.14 
             | 
            
             g/cm³ 
             | 
            ASTM D792 | 
| 
             Molding Shrinkage - Flow 
             | 
            
             1.3 to 1.6 
             | 
            
             % 
             | 
            ASTM D955 | 
| 
             Water Absorption (24 hr) 
             | 
            
             1.2 
             | 
            
             % 
             | 
            ASTM D570 | 
| Hardness | 
             Nominal Value 
             | 
            
             Unit 
             | 
            
             Test Method 
             | 
        
| 
             Rockwell Hardness 
             | 
            ASTM D785 | ||
| 
             M-Scale 
             | 
            
             86 
             | 
            
             | 
            |
| 
             R-Scale 
             | 
            
             121 
             | 
            
             | 
            
| Mechanical | 
             Nominal Value 
             | 
            
             Unit 
             | 
            
             Test Method 
             | 
        
| 
             Tensile Strength (Yield) 
             | 
            
             91.0 
             | 
            
             MPa 
             | 
            ASTM D638 | 
| 
             Tensile Elongation (Break) 
             | 
            
             12 
             | 
            
             % 
             | 
            ASTM D638 | 
| 
             Flexural Modulus 
             | 
            
             3170 
             | 
            
             MPa 
             | 
            ASTM D790 | 
| 
             Flexural Strength (Yield) 
             | 
            
             119 
             | 
            
             MPa 
             | 
            ASTM D790 | 
| 
             Compressive Strength 
             | 
            
             102 
             | 
            
             MPa 
             | 
            ASTM D695 | 
| Impact | 
             Nominal Value 
             | 
            
             Unit 
             | 
            
             Test Method 
             | 
        
| 
             Notched Izod Impact (23°C, 3.18 mm) 
             | 
            
             37 
             | 
            
             J/m 
             | 
            ASTM D256 | 
| Thermal | 
             Nominal Value 
             | 
            
             Unit 
             | 
            
             Test Method 
             | 
        
| 
             Deflection Temperature Under Load 
             | 
            ASTM D648 | ||
| 
             0.45 MPa, Unannealed 
             | 
            
             196 
             | 
            
             °C 
             | 
            |
| 
             1.8 MPa, Unannealed 
             | 
            
             78.9 
             | 
            
             °C 
             | 
            |
| 
             Melting Temperature 
             | 
            
             254 to 266 
             | 
            
             °C 
             | 
            |
| 
             CLTE - Flow 
             | 
            
             0.000072 
             | 
            
             cm/cm/°C 
             | 
            ASTM D696 | 
| 
             Thermal Conductivity 
             | 
            
             0.25 
             | 
            
             W/m/K 
             | 
            ASTM C177 | 
| Electrical | 
             Nominal Value 
             | 
            
             Unit 
             | 
            
             Test Method 
             | 
        
| 
             Volume Resistivity 
             | 
            
             3.9E+13 
             | 
            
             ohm·cm 
             | 
            ASTM D257 | 
| 
             Dielectric Strength 
             | 
            
             18 
             | 
            
             kV/mm 
             | 
            ASTM D149 | 